Emergency Combination Boiler Servicing St Mary Axe

Look No Further

Over 20 years of experience in specialised trades has led us to become your on stop service for all services you require.

Open 24/7

We offer a dedicated service 365 days of the year. We are always here to help in an emergency!

Call Us Today

We work with all businesses and individuals. Call us now on Telephone: 07801295368

How Combination Boiler Works

The combination boiler description applies to an indirect combination boiler where the domestic hot water is heated in a secondary calorifier. See below for more about a direct combination boiler. Our projects section also contains lots of information about central heating of all kinds including oil fired.

 

Combination boilers combine the functions of a central heating boiler and an instantaneous multi point water heater. They give priority, in the main, to the supply of domestic hot water (dhw). The combination boiler has all its operating components contained within the casing and is typically designed for use within a sealed central heating system.

 

Installation is made easier by incorporating an expansion vessel, thus eliminating the need for a feed and expansion cistern in the roof space. Like an ordinary boiler it will have a gas fired burner and a heat exchanger. The waterways of both form part of the central heating system. In most of the early designs of combination boiler, hot water from the heat exchanger passes to a diverter valve, which directs the flow to a domestic hot water calorifier or central heating circuit. The calorifier is tightly packed with small copper tubes, through which secondary water flows the moment the hot water draw off is opened. As the water flows it picks up heat from the surrounding primary water in the calorifier. The central heating system is pressurised and needs a relief valve to protect against any build up of pressure in the system.

 

A pressure gauge on the appliance indicates the operating pressure. A by-pass, connected across the primary flow and return, ensures that an adequate flow of water is maintained. This by-pass may, or may not be a built in feature of the appliance.

 

The flue arrangements for combination boilers may be open, room sealed, fan assisted & room sealed, fan assisted open, miniature flue/condensing or se-duct. The primary heating circuit of combination boilers should be pre-commissioned, cleansed and treated with a corrosion protector in the same way as any other heating system. In hard water areas, the secondary domestic hot water should be treated with an in-line scale reducer or water softer (See projects section for info on both of these) This will prevent the build up of limescale on the instantaneous water heater and the accompanying reduction in flow rate and water outlet temperature.

 

With a direct combination boiler the secondary water is heated in one of two ways. The water may pass through pipes which run down the inside, or next to the primary pipes in the heat exchanger, or by passing through a separate heat exchanger which is bolted on top of the main heat exchanger. A direct combination boiler does not need a diverter valve or a secondary calorifier.

 

In a domestic hot water system where the (condensing) boiler is a replacement for an existing storage cylinder system or a conventional boiler, it is essential that all redundant pipework is removed to eliminate "dead legs" which can hold air and cause air locks. These can also cause cold spots and slow burner shut off.

images 25 

London GAS SAFE heating engineers

-Central Heating installation, replacement, repair, maintenance, fault finding

-System boiler Heating installation, replacement, repair, maintenance, fault finding

-Central Heating installation, replacement, repair, maintenance, fault finding


Whenever you need a new boiler installed. Advanced Professional Plumbing and Heating Services also makes sure you get value for your money from the top quality boilers like Valliant. They are designed to give you sufficient performance as a market leader in the UK. This is how we build up our reputation - just by giving the customer the best advice and focus what you get from what you spend – see www.vaillant.co.uk for more details

 

You also have different option. Look at Worcester Bosch and see more on www.worcester-bosch.co.uk

 

However, if you look for any other boilers to be installed or have any problems with these boilers like Ariston, Alpha, Baxi, Biasi, Ariston, Chaffoteaux, Ferroli, Glowworm, Halstead, Ideal, Jaguar, Johnson, Keston Myson , Ravenheat, Starley, Saunier Duvall, Potterton , Sime Vokera

24HR LPG Boiler Engineer In Finsbury, Maida Vale

We can carry out  24HR LPG Boiler Engineer   In Hanger Lane, W6 Barons Court W7 Boston Manor W7 Elthorne Park, Emergency Ariston boiler repair Hanwell W7 Boston Manor, Kensington, High Street ,LPG Heating Install  W7 Hanwell, W8 Kensington (central Kensington), W8 West Kilburn , W8  Kensington , W8  High Street Kensington,  W9 Warwick Avenue, W9 Maida Hill , W9 Westway ,Maida Hill, Maida Vale, W10 Ladbroke Grove, W10 Latimer Road , Maida Vale, Warwick Avenue , Warwick Park ,W10 Ladbroke Grove, W10 West Kilburn, Westway W10,  North Kensington, W11 Latimer Road W11 Notting Hill, Holland Park, W11 Holland Park, Notting Hill, W11 Notting Hill Gate Westbourne Grove, Goldhawk Road , W12 Shepherd's Bush, W12 Goldhawk Road , W12  Shepherds Bush, W12  Uxbridge Road, W12 White City  West London ,WC2E  Covent Garden, Westminster, WC2H  Leicester Square, Camden, Westminster WC2N  Charing Cross, Westminster WC2R  Somerset House, Westminster WC1, WC2, WC1A WC1X, WC1V, WC1R, WC1N, WC1H, WC1E, WC1B, WC2R, Central London WC2N, WC2H, WC2E, WC2B, Central London WC2A EC1 St Bartholomew's Hospital,  EC1M  Cleckenwell, Farringdon,  EC1N Hatton Garden,  EC1P Finsbury, Finsbury Estate (west) , EC1V  Finsbury, Moorfields Eye Hospital, EC1Y  St Luke's, Bunhill Fields EC2A, Shoreditch EC2M , Broadgate, Liverpool Street, Old Broad Street,Tower 42, Bank of England , EC2V  Guildhall, EC2Y  Barbican, EC3A  St Mary Axe, Aldgate, EC3M  Leadenhall, Lloyd's of London, EC1A, EC1Y, EC1V, EC1R, EC1P, EC1N, EC1M, EC2Y, EC2V, EC2R, EC2P, EC2N, EC2M, EC2A, EC3V, EC3R, EC3P, EC3N, EC3M, EC3BEC3AEC4YEC4VEC4REC4PEC4N,Central London,Fenchurch Street, EC3N  Tower Hill, Tower of London, EC4R  Monument, Billingsgate, EC3V  